<ErrorNumber>38183</ErrorNumber>
<ErrorFamily>Main Plot Control</ErrorFamily>
<ErrorMessage>
MPC: Drum speed &lt;Target drum speed&gt; is too fast for &lt;Target resolution&gt; DPI resolution, maximum is &lt;Maximum drum speed&gt; RPM
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Gravure</Text></ListItem>
<ListItem><Text>Japanese_Newspaper_OEM_Engine</Text></ListItem>
<ListItem><Text>Lotem_400_Fiber_Head_Machine</Text></ListItem>
<ListItem><Text>Lotem_800_Fiber_Head_Machine</Text></ListItem>
<ListItem><Text>Lotem_Quantum</Text></ListItem>
<ListItem><Text>Magnus_400</Text></ListItem>
<ListItem><Text>Magnus_800</Text></ListItem>
<ListItem><Text>Magnus_VLF</Text></ListItem>
<ListItem><Text>Slave_MCE_Firmware</Text></ListItem>
<ListItem><Text>Thermoflex</Text></ListItem>
<ListItem><Text>Think_Motion_Controller</Text></ListItem>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
For TH1.7x heads, we cannot exceed a certain stroke clock frequency (the rate
at which pixels are laid down on plate) due to hardware limitations in the head.
Therefore we impose a limit on the SCLK frequency.  If this limit is exceeded
by a particular plot configuration, then the only that can be done is to slow
down the drum speed.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><UnnumberedList>
<ListItem><Text>
Check the mainscan image resolution
</Text></ListItem>
<ListItem><Text>
Check the media configuration
</Text></ListItem>
</UnnumberedList></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The drum speed is too high
</Cause>
<Cause>
The mainscan image resolution is too high
</Cause>
<Parameter>
Target drum speed
The drum speed that is configured for the plot
</Parameter>
<Parameter>
Target resolution
The mainscan resolution that is configured for the plot
</Parameter>
<Parameter>
Maximum drum speed
The maximum drum speed that can be used for the current resolution
</Parameter>
<LastModified>
05-Jan-2005
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:11 2008 PST
</Updated>
<Links>
</Links>
</Error>